| Supply voltage: | 240 V / 50 Hz, AC |
| Time to full luminance: | 1 s |
| Lifetime: | 50 000 h |
| Power-on times before shutdown: | 40 000 x |
| Dimming: | NO / OPTIONAL DALI |
| Degree of protection: | IP66 |
| Degree of protection against mechanical shocks: | IK08 |
| LED driver: | OSRAM |
| Material: | PMMA glass fiber housing, PMMA diffuser, stainless steel mounts |
| Usage: | Ceiling, wall or floor installation |
| Operating temperature: | od -30°C do + 45°C |
| UV protection: | Diffuser and lamp housing with UV protection |
| Body Color: | Light Gray (RAL 7035) |
| Model | Power | Light flux | Efficiency | CCT | CRI | UGR | Exit angle | PF | Dimension |
|---|---|---|---|---|---|---|---|---|---|
| ORVIN 4012 | 25-40 W | 3000-5200 lm | 120-130 lm / W | 3000-5000 K | Ra >80 | <22 | >120° | 0,92 | 1190 x 95 x 75 mm |
| ORVIN 6015 | 35-60 W | 4200-7800 lm | 120-130 lm / W | 3000-5000 K | Ra >80 | <22 | >120° | 0,92 | 1490 x 95 x 75 mm |
| ORVIN-S 6015 | 35-60 W | 4200-7800 lm | 130-140 lm / W | 3000-5000 K | Ra >80 | <22 | >120° | 0,92 | 1490 x 95 x 75 mm |